项目背景与核心痛点

站前广场人流潮汐特征明显:列车到站15分钟内人流峰值是平峰的8倍,固定亮度照明要么挤爆要么空转。

设计标准与技术参数

主活动区维持15lx、出入口集散区30lx(CJJ45-2015交会区标准);出租车蓄车区与公交港湾垂直照度≥20lx保障车牌识别;全部回路接入客流数据联动调光。

曦韵解决方案与服务承诺

我们把照明回路与车站到发数据打通,列车进站前10分钟预亮、散场后30分钟缓降,全年综合能耗下降48%。

Project Pain Points

Station plazas show tidal footfall: passenger surges within 15 minutes of train arrivals hit eight times off-peak levels, so fixed-brightness lighting is either swamped or idling.

Design Standards & Technical Parameters

Main activity zones 15 lx, entrance gathering areas 30 lx (CJJ45-2015 conflict-area class); taxi and bus bays need vertical illuminance ≥20 lx for plate recognition; all circuits join data-linked dimming driven by passenger-flow analytics.

Our Solution & Commitment

We integrate lighting circuits with arrival-departure data: pre-illumination 10 minutes before arrivals, gentle ramp-down 30 minutes after dispersal — 48% annual energy saving.