项目背景与核心痛点

地下通道是治安敏感区:照度低了滋生案件,色温冷了显得阴森,人一少监控又看不清脸——三个问题互相纠缠。

设计标准与技术参数

地面维持照度15lx、夜间不低于10lx(CJJ45-2015人行地下通道标准),显色指数Ra≥80方便辨认人物衣着;出入口过渡区防眩光,避免内外亮度突变造成『白洞』不适。

曦韵解决方案与服务承诺

我们采用3000-4000K中性光+通道全线感应调光,人流越大越亮、深夜自动提升基础照度,安全感与能耗同时达标。

Project Pain Points

Underground passages are security-sensitive: low light breeds incidents, cold colour feels eerie, and with few pedestrians cameras cannot capture faces — three problems entangled.

Design Standards & Technical Parameters

Per CJJ45-2015 underground-footway standards: 15 lx maintained, no less than 10 lx at night, Ra≥80 to make clothing recognisable; glare-controlled entrances smooth the brightness transition and avoid white-tunnel discomfort.

Our Solution & Commitment

We combine 3000-4000K neutral light with full-length sensor dimming — brighter with more pedestrians, elevated base level at midnight — hitting both security and energy targets.